Railway Cables

450/750V Limited Fire Hazard Earthing Cables to SE774

Application

The single core signalling earth and power cables are used in safety signalling equipment rooms.

Standards

● SE774
● UNE 21027

Construction

Conductors
Stranded tinned copper conductors.

Insulation
Thermoplastic LSZH..

Electrical Characteristics at 20℃

Nominal Conductor Cross Section
mm²
1.0
4.0
6.0
16.0
35.0
Maximum DC Conductor Resistance
Ω/km
18.2
4.7
3.11
1.16
0.529
Voltage Rating
KV
0.45/0.75

Mechanical and Thermal Properties

Minimum Bending Radius: 7.5×OD
Temperature Range:-25℃ to +85℃ (during operation); -10℃ to +70℃ (during installation)

Dimensions And Weight

Cable Code
No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
No. & Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km
RF774-ES07Z-U-450/750V-1G1
1×1.0
1/1.13
0.6
4.0
28
RF774-ES07Z-U-450/750V-1G4
1×4.0
7/0.85
0.8
5.5
33
RF774-ES07Z-U-450/750V-1G6
1×6.0
7/1.04
0.8
6.1
90
RF774-ES07Z-U-450/750V-1G16
1×16.0
7/1.7
1.0
8.1
197
RF774-ES07Z-U-450/750V-1G35
1×35.0
19/1.53
1.2
10.9
389

U is changed to K if the stranding class is changed from class 2 to class 5